HOME

ABOUT US >

PRODUCTS >

SERVICE & SUPPORT >

SOLAR ACADEMY

CONTACT

HOME > SBP SERIES
Technical Data

Model

Max. Charging 

Current (A)*1

Max. Discharging 

Current (A)*1


Nominal Power 

Output (W)

Max. Apparent 

Power Output (VA)*4

Max. Apparent Power From Utility Grid (VA)

GW3600S-BP7575
368036807360
GW5000S-BP100100
5000*350009200

Model

Max. AC Current 

Output (A)

Max. AC Current From Utility Grid (A)


Max. Output Apparent 

Power (VA)*6

Peak Output Apparent 

Power (VA)*6[Back-up]

Max. Output 

Current (A)[Back-up]

GW3600S-BP1632
36804416, 10sec16
GW5000S-BP22.8*540
50005500, 10sec22.8

point.pngBattery Input Data
point.pngAC Output Data (On-grid)










Battery TypeLi-Ion or Lead-acid*1

Nominal Output Voltage (V)  230

Nominal Battery Voltage (V)48

Nominal Output Freqency (Hz)  50/60

Max. Charging Voltage (V)≤60 (Configurable)

Output Power Factor  ~1 (Adjustable from 0.8 leading to 0.8 lagging)

Battery Capacity (Ah)*250~2000

Output THDi (@Nominal Output  <3%

Charging Strategy for Li-Ion BatterySelf-adaption to BMS













point.pngAC Output Data (Back-up)
point.pngGeneral Data










Automatic Switch Time (ms)<10

Operating Temperature Range (°C)  -25~60

Nominal Output Voltage (V)230 (±2%)

Relative Humidity  0~95%

Nominal Ouput Frequency (Hz)50/60 (±0.2%)

Operating Altitude (m)  ≤4000

Output THDv (@Linear Load)<3%

Cooling  Natural Convection

Efficiency



Noise (dB)  <25

Max. Efficiency
95.5%




point.pngProtection

User Interface  LED & APP

Anti-islanding ProtectionIntegrated

Communication with BMS*7  RS485; CAN

Output Over Current ProtectionIntegrated

Communication with Meter  RS485

Output Short ProtectionIntegrated

Communicaiton with Portal  Wi-Fi

Output Over Voltage ProtectionIntegrated

Weight (kg)  18.5






Size (Width*Height*Depth mm)  347*432*190
point.png


Mounting  Wall Bracket





Protection Degree  IP65






Standby Self Consumption (W)  <15






Topology  High Frequency Isolation









point.pngCertifications & Standards










Grid RegulationAS/NZS 4777.2:2015, G83/2, G100, CEI 0-21, RD1699, UNE206006, VDE4105-AR-N, VDE0126-1-1, EN50438

Safety IEC62477-1, IEC62040-1

EMCEN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-4-16, EN 61000-4-18, EN 61000-4-29












*1: Lead-acid battery use refers to Approved Battery Options Statement .

The actual charge and discharge current also depends on the battery.

*2: Battery capacity could be not less than 100Ah where the back-up function is to be applied.

*3: 4600 for VDE0126-1-1&VDE-AR-N 4105 and CEI 0-21.

*4: For CEI 0-21 GW3600S-BP is 4050, GW5000S-BP is 5100; for VDE-AR-N4105 GW5000S-BP is 4600.

*5: 21.7A for AS4777.2.

*6: Can be reached only if battery capacity is enough, otherwise will shut down.

*7: The standard configuration is CAN.






Spec Download